3 In 1 TECAR Therapy Machine With 448k CET RET Probes For Physiotherapy






Category: TECAR Therapy Machine
Product Features
• Endogenous Thermal Therapy with 448kHz Radiofrequency
Utilizes 448kHz capacitive (CET) and resistive (RET) energy transfer to generate deep, therapeutic heat from within the body's tissues. This endogenous thermal effect significantly enhances therapy outcomes for pain relief, reduced inflammation, accelerated tissue repair, and muscle relaxation, establishing it as an essential tool for professional rehabilitative care.
• Integrated 3-in-1 Handpiece System for Holistic Treatment
Features a comprehensive suite including a CAP probe for muscular and circulatory issues, a RES probe for deep joint and connective tissue ailments, and an electromagnetic massage gun for cell activation and meridian dredging. This versatile system offers all-in-one solutions for conditions ranging from sports injuries and chronic pain to improving local circulation and mobility.
• Precision CET & RET Probes for Targeted Layers
Equipped with a CAP probe with 4 ceramic heads for treating superficial, hydrated tissues and a RES probe with 4 metal heads for penetrating dense, deep-structure areas. This allows practitioners to achieve precise and effective treatments by selecting the optimal energy transfer mode for specific body areas and tissue types.
• Smart 448kHz Frequency & Control for Safety and Efficacy
Operates at the medically recognized 448kHz frequency for optimal tissue penetration and patient comfort, avoiding nerve over-stimulation. Coupled with intelligent control systems, it ensures consistent, safe, and reliable energy delivery for a comfortable and effective therapy experience every session.
• Versatile Application
Effectively treats a wide spectrum of issues including muscle strain, joint pain, tendonitis, neck and back pain, plantar fasciitis, and post-exercise recovery. Its ability to address both superficial and deep-layer conditions makes it a complete solution for personalized rehabilitation and pain management protocols.
Technical Principles
The fundamental principle of the machine is Endogenous Thermal Therapy ("endogenous" meaning "from within").
Unlike traditional heating methods (like hot packs) that transfer heat from the outside in, this device uses a safe 448 kHz radiofrequency current.
This current penetrates the body's tissues and causes charged particles (ions) and water molecules within the cells to oscillate rapidly billions of times per second. This internal friction generates deep, gentle, and therapeutic heat from within the tissue itself.
This "endogenous heat" leads to several key therapeutic effects:
-Vasodilation: Significant increase in blood circulation, bringing more oxygen and nutrients while removing metabolic waste and inflammatory mediators.
-Increased Cell Membrane Permeability: Enhances the exchange of fluids and ions across cell membranes, optimizing the environment for repair.
-Analgesia: Soothes nerve endings and interferes with pain signals.
-Muscle Relaxation: Reduces spasms and tension.
-Accelerated Tissue Repair: Promotes the healing process in muscles, tendons, and ligaments.
Handle Functions
CAP Handpiece (Capacitive Electrode)
Principle: Works in Capacitive Mode (CET). It uses an insulating plate to create a 448 kHz electric field that concentrates energy in superficial and intermediate tissues, generating deep, therapeutic heat from within.
Target Tissues: Muscles, blood vessels, lymphatic fluid, and soft tissue.
Primary Effect: Produces a diffuse heating sensation to relax muscles, increase local circulation, reduce inflammation and edema, and accelerate soft tissue repair.
RES Handpiece (Resistive Electrode)
Principle: Works in Resistive Mode (RET). The 448 kHz current flows directly to penetrate deeper, targeting dense, high-resistance tissues.
Target Tissues: Bones, joints, tendons, ligaments, and scar tissue.
Primary Effect: Provides a deep, focused, and penetrating heat to address joint stiffness, deep inflammation, tendonitis, and ligament pain.
JMD Massage Gun Handpiece (with Electromagnetic Bio-Currents)
Principle: This handpiece operates on an advanced principle that combines percussive therapy with electromagnetic bio-currents. It not only provides deep mechanical pulses but also delivers specific electromagnetic frequencies to stimulate the body's own biological currents.
Primary Mechanisms & Effects:
-Cell Activation: The electromagnetic bio-currents help to stimulate and activate cells, promoting cellular repair and regeneration.
-Meridian Dredging & Improved Blockage: Based on traditional principles, it helps to unblock meridians (energy pathways), promote energy (Qi) and blood flow, and improve stagnation.
-Promotes Blood Circulation: The combined percussive and electromagnetic action significantly enhances local microcirculation.
-Pain Relief: Effectively addresses a wide range of common conditions.
In the Box
1 x Main Unit
1 x CAP Probe
4 x Ceramic Conduction Head
1 x RES Probe
4 x Metal Conduction Head
1 x JMD Massage Gun
1 x Electrode Pad
1 x Power Cord
1 x User Manual






Payment options
The checkout page shows the payment options available for your order.
Processing & transit
Compare the processing window with the estimated transit time.
Standard Shipping: Handling (business days) 0–1; Transit (business days) 7–15.
Express Shipping: Handling (business days) 0–1; Transit (business days) 7–15.
View policyRefund processing
Merchant processing and bank posting are separate steps.
Please contact us for the refund processing timeframe before returning an item.
View policyShipping services
Use the details for the destination and service you select.
Standard Shipping · United States: $0.00
Express Shipping · United States: $3.99
View policyReturn terms
Follow the stated return method and include your order reference.
United States · Return window (days after delivery): 30. Return method: By mail. Return postage: Seller pays.
View policy
